#!/bin/bash # Define global functions function apply_Dell_profile () { ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x01 0x01 > /dev/null CURRENT_FAN_CONTROL_PROFILE="Dell default dynamic fan control profile" } function apply_user_profile () { ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x01 0x00 > /dev/null ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x02 0xff $HEXADECIMAL_FAN_SPEED > /dev/null CURRENT_FAN_CONTROL_PROFILE="User static fan control profile ($DECIMAL_FAN_SPEED%)" } function enable_third_party_PCIe_card_Dell_default_cooling_response () { # We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly ipmitool -I $LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null } function disable_third_party_PCIe_card_Dell_default_cooling_response () { # We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly ipmitool -I $LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null } # Returns : # - 0 if third-party PCIe card Dell default cooling response is currently DISABLED # - 1 if third-party PCIe card Dell default cooling response is currently ENABLED # - 2 if the current status returned by ipmitool command output is unexpected # function is_third_party_PCIe_card_Dell_default_cooling_response_disabled() { # THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE=$(ipmitool -I $LOGIN_STRING raw 0x30 0xce 0x01 0x16 0x05 0x00 0x00 0x00) # if [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 01 00 00" ]; then # return 0 # elif [ "$THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" == "16 05 00 00 00 05 00 00 00 00" ]; then # return 1 # else # echo "Unexpected output: $THIRD_PARTY_PCIE_CARD_COOLING_RESPONSE" >&2 # return 2 # fi # } # Prepare traps in case of container exit function gracefull_exit () { apply_Dell_profile enable_third_party_PCIe_card_Dell_default_cooling_response echo "/!\ WARNING /!\ Container stopped, Dell default dynamic fan control profile applied for safety." exit 0 } trap 'gracefull_exit' SIGQUIT SIGKILL SIGTERM # Prepare, format and define initial variables #readonly DELL_FRESH_AIR_COMPLIANCE=45 if [[ $FAN_SPEED == 0x* ]] then DECIMAL_FAN_SPEED=$(printf '%d' $FAN_SPEED) HEXADECIMAL_FAN_SPEED=$FAN_SPEED else DECIMAL_FAN_SPEED=$FAN_SPEED HEXADECIMAL_FAN_SPEED=$(printf '0x%02x' $FAN_SPEED) fi # Log main informations given to the container echo "Idrac/IPMI host: $IDRAC_HOST" if [[ $IDRAC_HOST == "local" ]] then LOGIN_STRING='open' else echo "Idrac/IPMI username: $IDRAC_USERNAME" echo "Idrac/IPMI password: $IDRAC_PASSWORD" LOGIN_STRING="lanplus -H $IDRAC_HOST -U $IDRAC_USERNAME -P $IDRAC_PASSWORD" fi echo "Fan speed objective: $DECIMAL_FAN_SPEED%" echo "CPU temperature treshold: $CPU_TEMPERATURE_TRESHOLD°C" echo "Check interval: ${CHECK_INTERVAL}s" echo "" # Prepare required variables and constants readonly TABLE_HEADER_PRINT_INTERVAL=10 i=$TABLE_HEADER_PRINT_INTERVAL IS_DELL_PROFILE_APPLIED=true # Start monitoring while true; do sleep $CHECK_INTERVAL & SLEEP_PROCESS_PID=$! DATA=$(ipmitool -I $LOGIN_STRING sdr type temperature | grep degrees) INLET_TEMPERATURE=$(echo "$DATA" | grep Inlet | grep -Po '\d{2}' | tail -1) EXHAUST_TEMPERATURE=$(echo "$DATA" | grep Exhaust | grep -Po '\d{2}' | tail -1) CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}') CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}') CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}') CPU1_OVERHEAT () { [ $CPU1_TEMPERATURE -gt $CPU_TEMPERATURE_TRESHOLD ]; } CPU2_OVERHEAT () { [ $CPU2_TEMPERATURE -gt $CPU_TEMPERATURE_TRESHOLD ]; } COMMENT=" -" if CPU1_OVERHEAT then apply_Dell_profile if ! $IS_DELL_PROFILE_APPLIED then IS_DELL_PROFILE_APPLIED=true if CPU2_OVERHEAT then COMMENT="CPU 1 and CPU 2 temperatures are too high. Dell default dynamic fan control profile applied." else COMMENT="CPU 1 temperature is too high. Dell default dynamic fan control profile applied." fi fi elif CPU2_OVERHEAT then apply_Dell_profile if ! $IS_DELL_PROFILE_APPLIED then IS_DELL_PROFILE_APPLIED=true COMMENT="CPU 2 temperature is too high. Dell default dynamic fan control profile applied." fi else apply_user_profile if $IS_DELL_PROFILE_APPLIED then COMMENT="CPU temperature decreased and is now OK (<= $CPU_TEMPERATURE_TRESHOLD°C). User's fan control profile applied." IS_DELL_PROFILE_APPLIED=false fi fi # Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response # No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container if $DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE then disable_third_party_PCIe_card_Dell_default_cooling_response THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Disabled" else enable_third_party_PCIe_card_Dell_default_cooling_response THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled" fi # Print temperatures array if [ $i -ge $TABLE_HEADER_PRINT_INTERVAL ] then echo " ------- Temperatures -------" echo " Date & time Inlet CPU 1 CPU 2 Exhaust Active fan speed profile Third-party PCIe card Dell default cooling response Comment" i=0 fi printf "%12s %3d°C %3d°C %3d°C %5d°C %40s %51s %s\n" "$(date +"%d-%m-%y %H:%M:%S")" $INLET_TEMPERATURE $CPU1_TEMPERATURE $CPU2_TEMPERATURE $EXHAUST_TEMPERATURE "$CURRENT_FAN_CONTROL_PROFILE" "$THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS" "$COMMENT" ((i++)) wait $SLEEP_PROCESS_PID done