Adding options for 14gen Dell servers via env var
This commit is contained in:
parent
dcf41e0cdc
commit
d1bf241be2
@ -35,10 +35,24 @@ function retrieve_temperatures () {
|
||||
|
||||
# Parse CPU data
|
||||
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}')
|
||||
if $14_GEN
|
||||
then
|
||||
# 14 Gen server
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||
else
|
||||
# 14 Gen or older
|
||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}')
|
||||
fi
|
||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||
then
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||
if $14_GEN
|
||||
then
|
||||
# 14 Gen server
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $4;}')
|
||||
else
|
||||
# 14 Gen or older
|
||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||
fi
|
||||
else
|
||||
CPU2_TEMPERATURE="-"
|
||||
fi
|
||||
@ -57,12 +71,26 @@ function retrieve_temperatures () {
|
||||
|
||||
function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
|
||||
if $14_GEN
|
||||
then
|
||||
# 14 Gen Server
|
||||
continue
|
||||
else
|
||||
# 13 Gen or older server
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x00 0x00 0x00 > /dev/null
|
||||
fi
|
||||
}
|
||||
|
||||
function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
|
||||
if $14_GEN
|
||||
then
|
||||
# 14 Gen Server
|
||||
continue
|
||||
else
|
||||
# 13 Gen or older server
|
||||
ipmitool -I $IDRAC_LOGIN_STRING raw 0x30 0xce 0x00 0x16 0x05 0x00 0x00 0x00 0x05 0x00 0x01 0x00 0x00 > /dev/null
|
||||
fi
|
||||
}
|
||||
|
||||
# Returns :
|
||||
|
||||
@ -15,6 +15,7 @@ RUN chmod 0777 /Dell_iDRAC_fan_controller.sh
|
||||
ENV IDRAC_HOST local
|
||||
#ENV IDRAC_USERNAME root
|
||||
#ENV IDRAC_PASSWORD calvin
|
||||
ENV 14_GEN false
|
||||
ENV FAN_SPEED 5
|
||||
ENV CPU_TEMPERATURE_THRESHOLD 50
|
||||
ENV CHECK_INTERVAL 60
|
||||
|
||||
@ -147,6 +147,7 @@ All parameters are optional as they have default values (including default iDRAC
|
||||
- `CPU_TEMPERATURE_THRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C).
|
||||
- `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s).
|
||||
- `DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE` parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. **Default** value is false.
|
||||
- `14_GEN` parameter that disabled 3rd party PCI calls and outputs CPU temperatures correctly for 14th Gen Dell servers, ex Dell r640, 740 series. Must have idrac 3.30.30.30 or older. **Default** value is false.
|
||||
|
||||
<p align="right">(<a href="#top">back to top</a>)</p>
|
||||
|
||||
|
||||
Loading…
Reference in New Issue
Block a user