Cant start env variable with numbers
This commit is contained in:
parent
d1bf241be2
commit
ae1fe1edcb
@ -35,7 +35,7 @@ function retrieve_temperatures () {
|
|||||||
|
|
||||||
# Parse CPU data
|
# Parse CPU data
|
||||||
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
|
local CPU_DATA=$(echo "$DATA" | grep "3\." | grep -Po '\d{2}')
|
||||||
if $14_GEN
|
if $DELL_14_GEN
|
||||||
then
|
then
|
||||||
# 14 Gen server
|
# 14 Gen server
|
||||||
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
|
||||||
@ -45,7 +45,7 @@ function retrieve_temperatures () {
|
|||||||
fi
|
fi
|
||||||
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
if $IS_CPU2_TEMPERATURE_SENSOR_PRESENT
|
||||||
then
|
then
|
||||||
if $14_GEN
|
if $DELL_14_GEN
|
||||||
then
|
then
|
||||||
# 14 Gen server
|
# 14 Gen server
|
||||||
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $4;}')
|
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $4;}')
|
||||||
@ -71,7 +71,7 @@ function retrieve_temperatures () {
|
|||||||
|
|
||||||
function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||||
if $14_GEN
|
if $DELL_14_GEN
|
||||||
then
|
then
|
||||||
# 14 Gen Server
|
# 14 Gen Server
|
||||||
continue
|
continue
|
||||||
@ -83,7 +83,7 @@ function enable_third_party_PCIe_card_Dell_default_cooling_response () {
|
|||||||
|
|
||||||
function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
function disable_third_party_PCIe_card_Dell_default_cooling_response () {
|
||||||
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
# We could check the current cooling response before applying but it's not very useful so let's skip the test and apply directly
|
||||||
if $14_GEN
|
if $DELL_14_GEN
|
||||||
then
|
then
|
||||||
# 14 Gen Server
|
# 14 Gen Server
|
||||||
continue
|
continue
|
||||||
|
|||||||
@ -15,7 +15,7 @@ RUN chmod 0777 /Dell_iDRAC_fan_controller.sh
|
|||||||
ENV IDRAC_HOST local
|
ENV IDRAC_HOST local
|
||||||
#ENV IDRAC_USERNAME root
|
#ENV IDRAC_USERNAME root
|
||||||
#ENV IDRAC_PASSWORD calvin
|
#ENV IDRAC_PASSWORD calvin
|
||||||
ENV 14_GEN false
|
ENV DELL_14_GEN false
|
||||||
ENV FAN_SPEED 5
|
ENV FAN_SPEED 5
|
||||||
ENV CPU_TEMPERATURE_THRESHOLD 50
|
ENV CPU_TEMPERATURE_THRESHOLD 50
|
||||||
ENV CHECK_INTERVAL 60
|
ENV CHECK_INTERVAL 60
|
||||||
|
|||||||
@ -147,7 +147,7 @@ All parameters are optional as they have default values (including default iDRAC
|
|||||||
- `CPU_TEMPERATURE_THRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C).
|
- `CPU_TEMPERATURE_THRESHOLD` parameter is the T°junction (junction temperature) threshold beyond which the Dell fan mode defined in your BIOS will become active again (to protect the server hardware against overheat). **Default** value is 50(°C).
|
||||||
- `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s).
|
- `CHECK_INTERVAL` parameter is the time (in seconds) between each temperature check and potential profile change. **Default** value is 60(s).
|
||||||
- `DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE` parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. **Default** value is false.
|
- `DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE` parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. **Default** value is false.
|
||||||
- `14_GEN` parameter that disabled 3rd party PCI calls and outputs CPU temperatures correctly for 14th Gen Dell servers, ex Dell r640, 740 series. Must have idrac 3.30.30.30 or older. **Default** value is false.
|
- `DELL_14_GEN` parameter that disabled 3rd party PCI calls and outputs CPU temperatures correctly for 14th Gen Dell servers, ex Dell r640, 740 series. Must have idrac 3.30.30.30 or older. **Default** value is false.
|
||||||
|
|
||||||
<p align="right">(<a href="#top">back to top</a>)</p>
|
<p align="right">(<a href="#top">back to top</a>)</p>
|
||||||
|
|
||||||
|
|||||||
Loading…
Reference in New Issue
Block a user