This commit is contained in:
Tigerblue77 2023-02-03 21:07:33 +00:00
commit 3c084c5c4e

View File

@ -1,12 +1,16 @@
#!/bin/bash
# Define global functions
# This function applies Dell's default dynamic fan control profile
function apply_Dell_profile () {
# Use ipmitool to send the raw command to set fan control to Dell default
ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x01 0x01 > /dev/null
CURRENT_FAN_CONTROL_PROFILE="Dell default dynamic fan control profile"
}
# This function applies a user-specified static fan control profile
function apply_user_profile () {
# Use ipmitool to send the raw command to set fan control to user-specified value
ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x01 0x00 > /dev/null
ipmitool -I $LOGIN_STRING raw 0x30 0x30 0x02 0xff $HEXADECIMAL_FAN_SPEED > /dev/null
CURRENT_FAN_CONTROL_PROFILE="User static fan control profile ($DECIMAL_FAN_SPEED%)"
@ -47,12 +51,12 @@ function gracefull_exit () {
exit 0
}
# Trap the signals for container exit and run gracefull_exit function
trap 'gracefull_exit' SIGQUIT SIGKILL SIGTERM
# Prepare, format and define initial variables
#readonly DELL_FRESH_AIR_COMPLIANCE=45
# Check if FAN_SPEED variable is in hexadecimal format, if not convert it to hexadecimal
if [[ $FAN_SPEED == 0x* ]]
then
DECIMAL_FAN_SPEED=$(printf '%d' $FAN_SPEED)
@ -64,6 +68,8 @@ fi
# Log main informations given to the container
echo "Idrac/IPMI host: $IDRAC_HOST"
# Check if the Idrac host is set to 'local', and set the LOGIN_STRING accordingly
if [[ $IDRAC_HOST == "local" ]]
then
LOGIN_STRING='open'
@ -72,21 +78,25 @@ else
echo "Idrac/IPMI password: $IDRAC_PASSWORD"
LOGIN_STRING="lanplus -H $IDRAC_HOST -U $IDRAC_USERNAME -P $IDRAC_PASSWORD"
fi
# Log the fan speed objective, CPU temperature threshold, and check interval
echo "Fan speed objective: $DECIMAL_FAN_SPEED%"
echo "CPU temperature treshold: $CPU_TEMPERATURE_TRESHOLD°C"
echo "Check interval: ${CHECK_INTERVAL}s"
echo ""
# Prepare required variables and constants
# Define the interval for printing
readonly TABLE_HEADER_PRINT_INTERVAL=10
i=$TABLE_HEADER_PRINT_INTERVAL
IS_DELL_PROFILE_APPLIED=true
# Start monitoring
while true; do
# Sleep for the specified interval before taking another reading
sleep $CHECK_INTERVAL &
SLEEP_PROCESS_PID=$!
# Retrieve sensor data using ipmitool
DATA=$(ipmitool -I $LOGIN_STRING sdr type temperature | grep degrees)
INLET_TEMPERATURE=$(echo "$DATA" | grep Inlet | grep -Po '\d{2}' | tail -1)
EXHAUST_TEMPERATURE=$(echo "$DATA" | grep Exhaust | grep -Po '\d{2}' | tail -1)
@ -94,43 +104,46 @@ while true; do
CPU1_TEMPERATURE=$(echo $CPU_DATA | awk '{print $1;}')
CPU2_TEMPERATURE=$(echo $CPU_DATA | awk '{print $2;}')
# Define functions to check if CPU1 and CPU2 temperatures are above the threshold
CPU1_OVERHEAT () { [ $CPU1_TEMPERATURE -gt $CPU_TEMPERATURE_TRESHOLD ]; }
CPU2_OVERHEAT () { [ $CPU2_TEMPERATURE -gt $CPU_TEMPERATURE_TRESHOLD ]; }
# Initialize a variable to store comments
COMMENT=" -"
# Check if CPU1 is overheating and apply Dell profile if true
if CPU1_OVERHEAT
then
apply_Dell_profile
# Set the flag to indicate that Dell profile is applied
if ! $IS_DELL_PROFILE_APPLIED
then
IS_DELL_PROFILE_APPLIED=true
if CPU2_OVERHEAT
then
COMMENT="CPU 1 and CPU 2 temperatures are too high. Dell default dynamic fan control profile applied."
else
COMMENT="CPU 1 temperature is too high. Dell default dynamic fan control profile applied."
fi
fi
elif CPU2_OVERHEAT
then
apply_Dell_profile
if ! $IS_DELL_PROFILE_APPLIED
if CPU2_OVERHEAT
then
IS_DELL_PROFILE_APPLIED=true
COMMENT="CPU 2 temperature is too high. Dell default dynamic fan control profile applied."
COMMENT="CPU 1 and CPU 2 temperatures are too high, Dell default dynamic fan control profile applied for safety"
else
COMMENT="CPU 1 temperature is too high, Dell default dynamic fan control profile applied for safety"
fi
else
apply_user_profile
if $IS_DELL_PROFILE_APPLIED
# Check if CPU2 is overheating and apply Dell profile if true
if CPU2_OVERHEAT
then
COMMENT="CPU temperature decreased and is now OK (<= $CPU_TEMPERATURE_TRESHOLD°C). User's fan control profile applied."
IS_DELL_PROFILE_APPLIED=false
apply_Dell_profile
if ! $IS_DELL_PROFILE_APPLIED
then
IS_DELL_PROFILE_APPLIED=true
fi
COMMENT="CPU 2 temperature is too high, Dell default dynamic fan control profile applied for safety"
else
# Check if user profile is applied and apply it if not
if $IS_DELL_PROFILE_APPLIED
then
apply_user_profile
IS_DELL_PROFILE_APPLIED=false
fi
fi
fi
# Enable or disable, depending on the user's choice, third-party PCIe card Dell default cooling response
# No comment will be displayed on the change of this parameter since it is not related to the temperature of any device (CPU, GPU, etc...) but only to the settings made by the user when launching this Docker container
@ -142,16 +155,15 @@ while true; do
enable_third_party_PCIe_card_Dell_default_cooling_response
THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS="Enabled"
fi
# Print temperatures array
if [ $i -ge $TABLE_HEADER_PRINT_INTERVAL ]
fi
# Print the results, including the current fan control profile and comment
if [ $i -eq $TABLE_HEADER_PRINT_INTERVAL ]
then
echo " ------- Temperatures -------"
echo " Date & time Inlet CPU 1 CPU 2 Exhaust Active fan speed profile Third-party PCIe card Dell default cooling response Comment"
echo "Time CPU1 CPU2 Inlet Exhaust Fan Control Profile Third-party PCIe card Dell default cooling response Comment"
i=0
fi
printf "%12s %3d°C %3d°C %3d°C %5d°C %40s %51s %s\n" "$(date +"%d-%m-%y %H:%M:%S")" $INLET_TEMPERATURE $CPU1_TEMPERATURE $CPU2_TEMPERATURE $EXHAUST_TEMPERATURE "$CURRENT_FAN_CONTROL_PROFILE" "$THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS" "$COMMENT"
((i++))
echo "$(date +%T) $CPU1_TEMPERATURE°C $CPU2_TEMPERATURE°C $INLET_TEMPERATURE°C $EXHAUST_TEMPERATURE°C $CURRENT_FAN_CONTROL_PROFILE $THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE_STATUS $COMMENT"
i=$(($i+1))
wait $SLEEP_PROCESS_PID
done